The Powercom KIM-2200 rack mount UPS batteries provide reliable backup power for IT and network systems. With a 2200VA capacity, lithium-ion technology, and hot-swappable design, they ensure uninterrupted power during outages. Key features include scalable runtime, remote monitoring, and compatibility with rack setups. Ideal for data centers and telecom, they balance efficiency, durability, and cost-effectiveness for critical infrastructure.
High Voltage Energy Storage Battery Rack-mounted System
Why Choose Lithium-Ion Batteries in the KIM-2200 Over Traditional Options?
Lithium-ion batteries offer 50% less weight, 3x faster charging, and 2-3x longer lifespan than VRLA batteries. They operate efficiently in 0-40°C environments and maintain consistent performance during frequent discharges. Though initially costlier, their lower total ownership cost makes them ideal for high-availability environments like data centers.
Lithium-ion technology also reduces operational complexity through built-in battery management systems (BMS) that monitor cell health in real time. Unlike VRLA batteries that require periodic equalization charges, the KIM-2200’s self-balancing cells maintain optimal voltage levels automatically. This technology also supports partial charging without memory effect – operators can top up batteries during brief power restorations without compromising capacity.
Feature | Lithium-Ion | VRLA |
---|---|---|
Cycle Life | 3,000-5,000 cycles | 300-500 cycles |
Charge Time | 2-4 hours | 8-16 hours |
Operating Temp Range | -20°C to 60°C | 15°C to 30°C |
What Maintenance Practices Extend the KIM-2200’s Lifespan?
Perform quarterly firmware updates, annual thermal scans, and bi-annual battery calibration. Keep ambient temperatures below 35°C and ensure 75% discharge depth maximum. Use Powercom’s Battery Refresh technology to recalibrate cells, extending lifespan to 8-10 years under optimal conditions.
Advanced maintenance should include infrared inspections of terminal connections every six months to detect resistance buildup. Use torque screwdrivers to maintain manufacturer-specified 4-6 N·m on battery terminals. For firmware updates, always validate compatibility with connected management systems through Powercom’s compatibility matrix. The UPS’s built-in diagnostics can predict 93% of failures when configured to generate monthly health reports analyzing these key parameters:
- Cell voltage variance (max 0.2V difference)
- Internal impedance trends
- Charge/discharge rate consistency
“The KIM-2200’s modular design sets a new standard for rack UPS systems. Unlike rigid models, its scalability lets enterprises add runtime incrementally, avoiding overprovisioning. The lithium-ion batteries are a game-changer—we’ve seen 40% lower cooling costs in client data centers due to their heat efficiency.”
— James Rivera, Power Systems Architect at Redway
- How long do KIM-2200 batteries last during a blackout?
- At full load (1980W), runtime is 5-7 minutes. With optional external packs (e.g., BPL-2200), this extends to 2+ hours. Partial loads (50%) provide 15-30 minutes.
- Is the KIM-2200 compatible with solar power systems?
- Yes, via its wide input voltage range (160-276V). However, solar integration requires a hybrid inverter with grid synchronization to prevent phase conflicts.
- What’s the warranty period for the KIM-2200 UPS?
- Powercom offers a 3-year comprehensive warranty, including battery replacement. Optional extensions up to 5 years are available for critical facilities.