FAQ Answer: A Size 24 marine battery is a 12-volt, Group 24 battery designed for marine use, offering 70-85 Ah capacity and deep-cycle performance. It powers trolling motors, electronics, and accessories while resisting vibration and corrosion. Ideal for small to mid-sized boats, it balances compact dimensions (10.25″ L x 6.75″ W x 8.75″ H) with reliable cranking power and durability in wet conditions.
24V 100Ah LiFePO4 Lithium Battery OEM Factory Wholesale
How Does the Size 24 Marine Battery Compare to Other Group Sizes?
Size 24 marine batteries are smaller than Group 27/31 but larger than Group 34, offering a middle ground between compact design and sufficient capacity. While Group 31 provides 100+ Ah for larger vessels, Size 24 delivers 70-85 Ah, ideal for boats under 22 feet. Its 12-volt output matches standard marine systems, unlike dual-purpose 24V setups requiring complex wiring.
12V 100Ah LiFePO4 Lithium Battery OEM Factory
What Are the Key Specifications of a Size 24 Marine Battery?
Standard specs include 10.25″ length x 6.75″ width x 8.75″ height, 12V voltage, 70-85 Ah capacity, and 650-800 MCA (Marine Cranking Amps). Deep-cycle variants withstand 400+ discharge cycles at 50% depth, while dual-purpose models blend starting (1000+ CCA) and cycling capabilities. Weight ranges 40-60 lbs, with AGM types being lighter and spill-proof versus flooded lead-acid counterparts.
24V 200Ah LiFePO4 Lithium Battery Factory (BCI Group 8D)
Why Choose AGM Over Flooded Batteries for Marine Use?
AGM (Absorbent Glass Mat) Size 24 batteries are maintenance-free, vibration-resistant, and spill-proof, making them 25% longer-lasting in marine environments. They recharge 1.5x faster than flooded batteries and perform better in cold temperatures. Though 30% pricier upfront, AGM’s 5-7 year lifespan vs. 3-5 years for flooded justifies the cost for frequent boaters prioritizing reliability.
LiFePO4 Marine Batteries Manufacturer, Factory, OEM In China
AGM batteries utilize fiberglass mat separators that absorb electrolyte, eliminating free liquid and reducing spill risks during rough waters. This design also minimizes internal resistance, allowing faster recharge rates compared to flooded batteries’ liquid electrolyte system. Marine applications benefit from AGM’s vibration resistance – crucial for engines and wave impacts. Testing shows AGM batteries maintain 95% capacity after 500 deep cycles, versus 70% for flooded types under identical conditions.
Feature | AGM | Flooded |
---|---|---|
Maintenance | None | Monthly checks |
Lifespan | 5-7 years | 3-5 years |
Recharge Time | 4-6 hours | 8-10 hours |
How to Optimize Charging for Maximum Battery Lifespan?
Use a 3-stage marine charger (bulk/absorption/float) with voltage limits: 14.4-14.6V bulk, 13.2-13.8V float. Avoid discharging below 50% capacity—a 85Ah battery shouldn’t drop below 42.5Ah. Recharge within 24 hours post-use. Temperature-compensated charging adds 0.028V/°C above 25°C. For storage, maintain 12.4V+ and charge monthly. AGM batteries require lower float voltages (13.2-13.4V) than flooded (13.8V).
Proper charging extends battery life by preventing sulfation. During bulk charging, 80% capacity is restored at maximum current. The absorption phase then slowly fills the remaining 20% to prevent overheating. Smart chargers automatically adjust based on battery state – a study showed they extend cycle life by 38% compared to basic chargers. For winter storage, disconnect batteries and store in climate-controlled spaces. Use a maintenance charger if leaving connected to marine electronics.
Charging Stage | Voltage Range | Duration |
---|---|---|
Bulk | 14.4-14.6V | 2-4 hours |
Absorption | 13.8-14.2V | 3-5 hours |
Float | 13.2-13.6V | Indefinite |
What Safety Precautions Are Critical for Marine Battery Installation?
Secure batteries in vented, non-conductive boxes with 0.5″ clearance from metal surfaces. Use marine-grade tinned cables (4AWG for 50A loads) and corrosion-resistant terminals coated in silicone grease. Install overcurrent protection (300A ANL fuses within 7″ of battery). Follow ABYC standards: no fuel/ignition sources within 12″, and hydrogen venting for flooded types. Always disconnect negative terminal first during maintenance.
12V 150Ah LiFePO4 Lithium Battery OEM Factory (BCI Group 31)
Expert Views: Redway Power Insights
“Modern Size 24 batteries now integrate carbon additives and enhanced plate alloys, boosting cycle life by 40% compared to 2019 models. We’re seeing a 22% annual growth in lithium-ion adoption, but AGM remains dominant for mid-price boats due to its 1,200+ cycle count at half the cost of LiFePO4 alternatives. Proper installation remains the #1 factor in real-world longevity.”
Conclusion
The Size 24 marine battery’s balance of compact dimensions and robust performance makes it the pragmatic choice for 65% of recreational boats under 25 feet. By selecting AGM technology, adhering to precision charging protocols, and implementing ABYC-compliant installations, users can achieve 5-7 years of reliable service—critical for marine environments where failure risks safety and costly rescues.
24V 200Ah LiFePO4 Lithium Battery Factory (BCI Group 8D)
FAQs
- How Long Does a Size 24 Marine Battery Last on a Single Charge?
- Runtime depends on load: a 85Ah battery running a 10A trolling motor lasts 8.5 hours at 100% discharge (practical 4.25 hours at 50% depth). With a 5A fishfinder and 2A stereo, total 17A draw reduces runtime to 5 hours. Always size batteries to 130% of calculated needs.
- Can Size 24 Batteries Be Used for Engine Starting?
- Dual-purpose models with 800+ MCA can start engines up to 5.0L displacement. Dedicated starting batteries are better for large V8s, but 24-size works for outboards under 150HP. Separate starting/deep-cycle batteries are ideal for systems exceeding 150A combined load.
- What’s the Ideal Replacement Cycle for Marine Batteries?
- Replace when capacity drops below 80% of rated Ah (typically 3-5 years). Conduct annual load tests: if voltage under 12.4V after 15% discharge indicates sulfation. Swollen cases or terminal corrosion exceeding 30% surface area also signal replacement needs.